Usuarios conectados
Actualmente hay 5950 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
TSS-SUB4000
TSS-SUB4000 Test Set Up and Procedure
SYSTEM AURAL SWEEP TEST Equipment needed: � Function/signal generator/sweep generator � Multimeter � RCA cables General Unit Function (UUT = Unit Under Test) Switches/knobs on the amplifier faceplate: Phase switch � either position Low Pass switch � Off RABOS switch � Off 1. From the signal generator, Connect both right and left line level inputs (RCA jacks) � to signal generator and UUT. Use Y-cable if necessary from mono source. 2. On the amplifier, turn the LEVEL control full Counterclockwise (Min). 3. Turn on generator, adjust to 125mV, 50 Hz. 4. Plug in UUT; turn the power switch ON. Turn LEVEL control full Clockwise (Max). 5. LED (on front panel) should now be Green; immediate bass response should be heard and felt from rear port tube opening. Sweep Function 1. Follow steps 1-5 above, using a sweep generator as a signal source. 2. Sweep generator from 20Hz to 1kHz. Listen to the cabinet and drivers for any rattles, clicks, buzzes or any other noises. If any unusual noises are heard, remove woofer and test. Driver Function (Woofer) 1. Remove woofer from cabinet (follow steps on exploded view page); detach + and - wire clips. 2. Check DC resistance of woofer; it should be 3.5 ohms±10%. 3. Connect a pair of speaker cables to driver terminals. Cables should be connected to an integrated amplifier fed by a signal generator. Turn on generator and adjust so that speaker level output is 5.0V. 4. Sweep generator from 20Hz to 1kHz. Listen to driver for any rubbing, buzzing, or other unusual noises.